Your name and signature record who did this check. They do not prove a licence.

Read it off the machine's hour meter, in hours. Last reading: 742 h.

Walk-around checks 38 questions

Fluids: oil level OK?
Fluids: coolant level OK?
Fluids: hydraulic level OK?
Greasing: when was it last done?

Grease points are due every 3 days or 30 machine hours, whichever comes first.

Safety devices present and working?

Seat belt, ROPS/FOPS, guards, horn, mirrors.

Paperwork on board?

SWMS, risk assessment and operator manual.

Defects from the previous shift noted and actioned?
Maker's operating instructions on the machine: read and understood
Chain and cable mechanisms: not slack, no damage
Chassis, boom sections and legs: no cracks or damage, pins and bolts secure

Include keeper plates and pins, and the level bubble if fitted.

Tyres, wheels, wheel nuts, castors and steering linkages: correct and secure

Most have solid or foam-filled tyres.

Hydraulic hoses and fuel system: no leaks or damage

Look for puddles on the ground.

Cables, wiring, limit switches and charger: no damage
Warning, operation and safe working load signs: present and readable

Include the electrical hazard decal, controls and wind rating.

Safe working load plate: fitted and readable
Harness, lanyard and energy absorber: no damage, anchor points secure

Fall arrest or restraint is mandatory on boom-type EWPs.

Platform floor, handrails and gates: secure, gates self-close, floor clear

If a rail is loose or a gate will not close, choose No.

Slide-out deck: moves smoothly and latches
Controls: undamaged and return to neutral when released
Control gaiters and seals: not worn, split or perished

Look at the ground controls and the platform controls.

Fibreglass parts: no cracks, especially where bonded to the boom
Any other pre-start checks the maker asks for: done
Last inspection tag or record: in date

The maintenance summary (3-monthly, annual and major inspections) is kept in the logbook.

Emergency stops and deadman: machine stops at both upper and lower controls

Allow for the time delay before the machine stops.

Ground controls: raise, lower and slew work
Platform controls: every movement works
Safety features and lockouts: outriggers, cut-outs, speed change-over

Mark off the ones this machine does not have.

Brakes and slew brake: no excessive run-on when tested

Some machines have a time delay before the brakes apply. Test slowly in a clear area. If it does not stop or hold, choose No.

Emergency descent and operator retrieval: works, then set back to normal

Test from the ground. Return the valve or control to the normal operating position.

Flashing lights and audible alarms: working
Any other operating checks the maker asks for: done
Tilt alarm: sounds when the machine is beyond its slope limit
Overload alarm and load sensing: working
Secondary guarding system: in place and working

Mark it off if the machine has none.

Boom envelope and height limits: stop the movement at the limit
Ground where you will raise the platform: firm and level

Choose N/A if you are not raising it yet.

Overhead power lines: checked and kept clear of the work area

Choose N/A if you are not raising it yet.

Fuel level: enough for the job

Leaks are covered by the hydraulic hose and fuel system check.

Sign off Demo Lift Co DL-45 boom (DEMO-HR01)

Describe anything wrong. Leave blank if nothing.

Machine safe to operate?

Choose No if you have any doubt. The machine will be tagged out.

Sign with your finger

A drawn signature is required. Use your finger or a stylus in the box. If you cannot sign here, ask the person in charge of this machine to help you before you start.